Additional electrodes on the Quartet™ LV lead provide more programmable pacing options than bipolar and tripolar equivalents - Université de Rennes Accéder directement au contenu
Article Dans Une Revue EP-Europace Année : 2017

Additional electrodes on the Quartet™ LV lead provide more programmable pacing options than bipolar and tripolar equivalents

Résumé

AIMS: The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). METHODS AND RESULTS: A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P \textless 0.05). Among the three modelled bipolar configurations, the lead configuration with the two most distal electrodes resulted in the highest number of viable pacing vectors. Among the four modelled tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. CONCLUSION: The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents

Dates et versions

hal-01301537 , version 1 (12-04-2016)

Identifiants

Citer

David O'Donnell, Johannes Sperzel, Bernard Thibault, Christopher Aldo Rinaldi, Carlo Pappone, et al.. Additional electrodes on the Quartet™ LV lead provide more programmable pacing options than bipolar and tripolar equivalents. EP-Europace, 2017, 19 (4), pp.588-595. ⟨10.1093/europace/euw039⟩. ⟨hal-01301537⟩
237 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More