Wireless power transfer in presence of a body

Abstract : A study of interactions between a human body and a wireless power transfer system has been presented. The system consists of two identical resonant coils driven by high quality factor loops. Four different exposure scenarios are considered using a high-resolution anatomical body model. Local specific absorption rate averaged over 10g of tissue is evaluated. Compliance with respect to the ICNIRP basic restrictions is also investigated followed by computing the maximum allowable input power. © 2016 IEEE.