Dosage de la thyroglobuline dans les liquides de rinçage d’aiguille de cytoponction ganglionnaire : influence des conditions pré-analytiques [Thyroglobulin assay in fluids from lymph node fine needle-aspiration washout: influence of pre-analytical conditions] - Université de Rennes Accéder directement au contenu
Article Dans Une Revue Annales de Biologie Clinique Année : 2017

Dosage de la thyroglobuline dans les liquides de rinçage d’aiguille de cytoponction ganglionnaire : influence des conditions pré-analytiques [Thyroglobulin assay in fluids from lymph node fine needle-aspiration washout: influence of pre-analytical conditions]

Résumé

The aim of this study was to evaluate the pre-analytical factors contributing to uncertainty in thyroglobulin measurement in fluids from fine-needle aspiration (FNA) washout of cervical lymph nodes. We studied pre-analytical stability, in different conditions, of 41 samples prepared with concentrated solutions of thyroglobulin (FNA washout or certified standard) diluted in physiological saline solution or buffer containing 6% albumin. In this buffer, over time, no changes in thyroglobulin concentrations were observed in all storage conditions tested. In albumin free saline solution, thyroglobulin recovery rates depended on initial sample concentrations and on modalities of their conservation (in conventional storage tubes, recovery mean was 56% after 3 hours-storage at room temperature and 19% after 24 hours-storage for concentrations ranged from 2 to 183 μg/L; recovery was 95%, after 3 hours or 24 hours-storage at room temperature, for a concentration of 5,656 μg/L). We show here that these results are due to non-specific adsorption of thyroglobulin in storage tubes, which depends on sample protein concentrations. We also show that possible contamination of fluids from FNA washout by plasma proteins do not always adequately prevent this adsorption. In conclusion, non-specific adsorption in storage tubes strongly contributes to uncertainty in thyroglobulin measurement in physiological saline solution. It is therefore recommended, for FNA washout, to use a buffer containing proteins provided by the laboratory.
Fichier non déposé

Dates et versions

hal-01518890 , version 1 (05-05-2017)

Identifiants

Citer

Florence Boux de Casson, Valérie Moal, Anne-Sophie Gauchez, Marie-Pierre Moineau, Corinne Sault, et al.. Dosage de la thyroglobuline dans les liquides de rinçage d’aiguille de cytoponction ganglionnaire : influence des conditions pré-analytiques [Thyroglobulin assay in fluids from lymph node fine needle-aspiration washout: influence of pre-analytical conditions]. Annales de Biologie Clinique, 2017, 75 (2), pp.173-180. ⟨10.1684/abc.2017.1225⟩. ⟨hal-01518890⟩
178 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More