Active-Distributed Temperature Sensing to continuously quantify vertical flow in boreholes - Université de Rennes Accéder directement au contenu
Article Dans Une Revue Water Resources Research Année : 2014

Active-Distributed Temperature Sensing to continuously quantify vertical flow in boreholes

Résumé

We show how a distributed borehole flowmeter can be created from armored Fiber Optic cables with the Active-Distributed Temperature Sensing (A-DTS) method. The principle is that in a flowing fluid, the difference in temperature between a heated and unheated cable is a function of the fluid velocity. We outline the physical basis of the methodology and report on the deployment of a prototype A-DTS flowmeter in a fractured rock aquifer. With this design, an increase in flow velocity from 0.01 to 0.3 m s21 elicited a 2.5 C cooling effect. It is envisaged that with further development this method will have applications where point measurements of borehole vertical flow do not fully capture combined spatiotemporal dynamics.
Fichier principal
Vignette du fichier
PL03305.pdf (572.72 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

insu-01005138 , version 1 (12-06-2014)

Identifiants

Citer

T. Read, Olivier Bour, J. S. Selker, V. F. Bense, Tanguy Le Borgne, et al.. Active-Distributed Temperature Sensing to continuously quantify vertical flow in boreholes. Water Resources Research, 2014, 50 (5), pp.3706-3713. ⟨10.1002/2014WR015273⟩. ⟨insu-01005138⟩